D&W Incorporated Homepage Shop our online store About D&W Contact D&W

ETERNABOND, INC.
Material Safety Data Sheet (TACTA01O)

This form is designed to meet the requirements of the U.S. Labor Department OSHA form no. 174.

SECTION I -- PRODUCT IDENTIFICATION

Product: ETERNABOND MOLDABLE SEALANT

Chemical Name: N/A
Chemical Family: Polyolefin and Synthetic Elastomer
Formula: N/A

HMIS/NFPA HAZARD RATINGS:

Health Hazard:
0
Flammability Hazard
1
Reactivity Hazard
0
SECTION II -- HAZARDOUS COMPONENTS

NONE

SECTION II -- PHYSICAL DATA


Boiling point range:
420 Degrees Fahrenheit
Vapor Pressure: N/A
Solubility in Water: Insoluble
Specific Gravity: 1.04 (adhesive)



Percent Volatile by Weight:
N/A
Evaporation Rate: N/A
Appearance and Odor: Black and white tapes or gray sealant

 

SECTION IV -- FIRE AND EXPLOSION HAZARD DATA

Flash Point and Method: 450 Degrees Fahrenheit COC
Flammable Limits: N/A
Extinguishing Media: Carbon dioxide, dry chemical, foam, water fog, and water spray
Special Fire Fighting Procedures: Use water spray to cool fire exposed surfaces and to protect personnel.
Unusual Fire and Explosion Hazards: None

SECTION V -- HEALTH HAZARD DATA

Permissible Exposure Level: N/A
Effects of Overexposure:

  • Eyes: N/A
  • Ingestion: Acute oral LD50 is greater than 10g/kg
  • Inhalation: N/A
  • Skin: N/A

Emergency and First Aid Procedures:

  • Eyes: Flush with water
  • Ingestion: Contact a physician
  • Inhalation: N/A
  • Skin: Remove with waterless hand cleaner. Wash with soap and water

Medical Conditions generally aggravated by exposure: N/A

Primary Routes of Entry:

  • Eyes: None
  • Ingestion: Not a normal exposure
  • Inhalation: None
  • Skin: None
Chemicals contained herein listed as carcinogens or potential carcinogens:
NTP: None IARC: None OSHA: None

SECTION VI -- REACTIVITY DATA

Stability: Stable
Conditions to Avoid: Overheating
Incompatibility (Material to Avoid): Avoid contact with strong oxidizing agents
Hazardous Decomposition Products: None
Hazardous Polymerization: Will not occur

SECTION V11 -- SPILL OR LEAK PROCEDURER

Steps to be taken in case material is released or spilled: Sweep up
Waste disposal method: Dispose of in accordance with Federal, State and local regulations

SECTION V111 -- SPECIAL PROTECTION INFORMATION

Respiratory Protection: N/A Eye Protection: Chemical goggles
Ventilation: N/A Protective Gloves: N/A

SECTION IX -- SPECIAL PRECAUTIONS


Precautions to be taken in handling and storing: Do not store near flame, heat or strong oxidizing agents.

SECTION X -- NOTES
Note: N/A = not applicable NE = not established
Issure Date: August 5, 1991 Issued By: John Bilstein (KK)
Revision Date: June 20, 1996 Review Date: April 19, 1999

Information herein is given in good faith and is, to the best of our knowledge and belief, accurate and reliable. However, since information herein was obtained, in part, from independent suppliers not under the direction and supervision of ETERNABOND, INC., ETERNABOND, INC., makes no warranty or representation, express or implied, that information is accurate, reliable, complete or representative. ETERNABOND, INC., warrants only that it has made no effort to censor other than trade secret information or to conceal deleterious aspects of its products. The data shown above in no way modifies, amends, or enlarges any specifications or warranty.

All components of this product are listed in the EPA/TSCA Inventory or Chemical Substances.

ETERNABOND

Permanent Waterproofing & Leak Repair Products

 

ETERNABOND ROOF SEAL/SUPER SEAL

SYSTEM DESCRIPTION
 
Bonding System
Pressure Sensitive
Backing

Multipolymer Alloy Film

Adhesive Elastomeric

PROPERTY
ENGLISH
TEST METHOD
Cathodic Disbondment

<0.6 in2 (30 days)
<1.2 in2 (30 days)

ASTM G 8
Adhesion* 9-20 lbs ./inch width
ASTM D 1000
Tensile Strength 30 lbs ./inch width  
Elongation >700%  
Dielectric Strength Exceeds 12 kV  
Backing 8 mils  
Adhesive 27 mils / 17 mils  

Conformability
Yes
@72°F
 
Yes
@50°F
 
Yes
@0°F

Impact Resistance

20 inch/lb.

ASTM G 14
Water Vapor Transmission .005 g/100 in2/24 hr. @ 100°F
ASTM E96 B
Water Absorption 0.5%
ASTM D 570
Leachable Chlorides None  

Listed values are typical and not to be considered as maximum or minimum

*Failure is cohesive, not adhesive