Chemicals contained herein
listed as carcinogens or potential carcinogens:
| NTP: None |
IARC: None |
OSHA: None |
SECTION VI
-- REACTIVITY DATA |
Stability: Stable
Conditions to Avoid: Overheating
Incompatibility (Material to Avoid):
Avoid contact with strong oxidizing
agents
Hazardous Decomposition Products: None
Hazardous Polymerization: Will
not occur
SECTION V11 -- SPILL OR LEAK
PROCEDURER
|
Steps to be taken in case material
is released or spilled: Sweep up
Waste disposal method: Dispose
of in accordance with Federal, State and local
regulations
SECTION V111
-- SPECIAL PROTECTION INFORMATION |
| Respiratory Protection:
N/A |
Eye Protection: Chemical
goggles |
| Ventilation: N/A |
Protective Gloves:
N/A |
SECTION IX
-- SPECIAL PRECAUTIONS |
Precautions to be taken in handling
and storing: Do not store near flame,
heat or strong oxidizing agents.
| Note: N/A = not applicable |
NE = not established |
| Issure Date: August 5,
1991 |
Issued By: John Bilstein
(KK) |
| Revision Date: June 20,
1996 |
Review Date: April 19,
1999 |
Information herein is given in good faith and
is, to the best of our knowledge and belief,
accurate and reliable. However, since information
herein was obtained, in part, from independent
suppliers not under the direction and supervision
of ETERNABOND, INC., ETERNABOND, INC., makes
no warranty or representation, express or implied,
that information is accurate, reliable, complete
or representative. ETERNABOND, INC., warrants
only that it has made no effort to censor other
than trade secret information or to conceal
deleterious aspects of its products. The data
shown above in no way modifies, amends, or enlarges
any specifications or warranty.
All components of this product are listed in
the EPA/TSCA Inventory or Chemical Substances.
ETERNABOND
Permanent
Waterproofing & Leak Repair Products
ETERNABOND
ROOF SEAL/SUPER SEAL
SYSTEM
DESCRIPTION |
|
Bonding System |
Pressure Sensitive |
| Backing |
Multipolymer Alloy Film |
| Adhesive |
Elastomeric |
PROPERTY |
ENGLISH |
TEST METHOD |
| Cathodic Disbondment |
<0.6 in2 (30 days)
<1.2 in2 (30 days)
|
ASTM G 8 |
| Adhesion* |
9-20 lbs ./inch width |
ASTM D 1000 |
| Tensile Strength |
30 lbs ./inch width |
|
| Elongation |
>700% |
|
| Dielectric Strength |
Exceeds 12 kV |
|
| Backing |
8 mils |
|
| Adhesive |
27 mils / 17 mils |
|
| Conformability |
Yes |
@72°F |
| |
Yes |
@50°F |
| |
Yes |
@0°F |
| Impact Resistance |
20 inch/lb. |
ASTM G
14 |
| Water Vapor Transmission |
.005 g/100 in2/24 hr. @ 100°F |
ASTM E96 B |
| Water Absorption |
0.5% |
ASTM D 570 |
| Leachable Chlorides |
None |
|
Listed values are typical and not to be considered
as maximum or minimum
*Failure is cohesive, not adhesive